IIR Direct method with MIP and Tan High Pass.
Cuthbert Nyack
The frequency response and Z plane poles for a low pass IIR filter with mirror image poles generated by the tan is shown in green in the applet below.
To design a filter with a gain of -1dB at 0.35ws and -50dB at
0.25ws. First set BL = 263 and WL = 188 to locate the frequencies. Now adjust N and fc/fs until the
requirements are met. This gives N = 10 and fc/fs = 0.34.
Changing nP shows the numerical values of the poles and changing Fn to 1
shows the quadratic factors necessary to realize the filter.
Return to page
index
COPYRIGHT © 1999, 2008 Cuthbert A. Nyack.